Return to Previous Page

RL series Reverse Osmosis System



The RL series reverse osmosis systems are designed for treating from wide range of water sources including municipal supplies, dam and river waters, bore and brackish water sources. These basic systems are designed to be simple to install, operate and require little maintenance. A membrane flush facility is standard and operates each time the system is started to assist with keeping the membranes clean. Continual monitoring of feedwater pressure, RO permeate quality and storage tank level is performed by PLC controller.

AIR ATOM‘s Reverse Osmosis systems are capable of removing salts as well as other impurities such as bacteria, sugars, proteins, dyes and constituents having a molecular weight greater than 150-250 dalton.


Category: .
  • Description

    Product Description

    Product Features:

    * Schedule 80 rigid pipe work
    * Stainless steel control valves and pump
    * Programmable PLC controller
    * Low feedwater pressure sensor
    * Permeate quality sensor & conductivity display
    * Storage tank level sensor input (24 VDC)
    * Permeate and reject flow rotameters
    * Adjustable pressure regulator valve
    * Auto flush (optional with permeate water)
    * Panel mount pressure gauges
    * Electrical mimic panel with status indicators
    * Electro-polished stainless steel frameSpecifications

    Specifications \ Models RL-2T RL-2.5T RL-3T RL-4T RL-6T RL-9T RL-12T
    Permeate Flow LPH 2000 2500 3000 4000 6000 9000 12000
    Module Qty & Size (4), 4″x80″ (5), 4″x80″ (4), 4″x120″ (4), 4″x40″ (2), 8″x80″ (3), 8″x120″ (3), 8″x160″
    Nominal Recovery 50-75%
    Motor (kw) 0.75  2.25 2.25 2.25 3 3 3
    Weight (kg) 43 43 43 43 43 43 43
    Dimension (mm) 530 x 530 x 1150
    Specifications \ Models RL-16T RL-20T RL-24T RL-30T RL-35T RL-45T RL-50T
    Permeate Flow LPH 16000 20000 24000 30000 35000 45000 50000
    Module Qty & Size (4), 8″x160″ (4), 8″x200″ (4), 8″x240″ (5), 8″x240″ (5), 8″x280″ (6), 8″x280″ (7), 8″x280″
    Nominal Recovery 50-75%
    Motor (kw) 0.75  2.25 2.25 2.25 3 3 3
    Weight (kg) 43 43 43 43 43 43 43
    Dimension (mm) 530 x 530 x 1150


    Feed Water Requirments

    pH: 3.0 : 10.0
    TDS: < 2,000 ppm (choose BW systems when exceed)
    Turbidity: < 1.0 NTU (required pre-treatment when exceed)
    SDI: < 5.0 (required pre-treatment when exceed)
    Hardness: < 50 ppm (required pre-treatment when exceed)
    Residual Chlorine: < 0.1 ppm (required pre-treatment when exceed)

    Feed water quality, pressures and flow rates have a significant impact on the performance of any reverse osmosis system. To ensure reliable and consistent long-term performance, it is important to supply feed water having the minimum specifications detailed below. If your feed water supply is marginal, you should consider using a feed water break tank and booster pump to supply the system.

     